Skylab Orbital Workshop Model Dsv Etc Support Stand

15 A9 Container Handling and Installation Kit (DSVT-372) This kit (Drawing No. 1B9121U) consisted of a forward support adapter, an aft support adapter, an A9 locker hoist, safety cable assembly, an A9 locker hoist beam assembly, and a support assembly to secure the container to the Model DSV7-311 Handling Cart (Figure 2.2.1U.U-39). There was no testing program on this system due to the fact that tight schedules and geographic dispersion of the principal experiments required that the equipment...

Dsvu

2.2.11*.U 10 Installation of Control Console M131 Model 2.2.1U-57 DSV7-31+8 2.2.11+* 1+-11 Motor Base Handling GSE Model DSV7-31+8 2.2.H+-58 2.2.11+.1+-12 Model DSV7-3I+9 Fork Lift - Configuration A 2.2.H+-59 2.2.ll*.l*-13 Model DSV7-3J+9 Fork Lift - Configuration B 2.2.1U60 2.2.11+.U-11* Model DSV7-31+9 Hoisting GSE for ESS Console and 2.2.1U-61 Metabolic Analyzer 2.2.ll*.l*-15 Model DSV7-3 '9 M171 Ergometer Handling GSE 2.2.1U-62 2.2*lU.4 (.6 Model DSV7-3'. 1 BMMD Hsndling GSE 2.2.1U-63...

Info

Potable Water - CL-4 Data from Samples Returned 2.2.11-342 from Orbit OWS Action Summary - System Water-Mission SL-2 2.2.11-350 OWS Action Summary - System Water-Mission SL-3 . . ll- i OWS Action Summary - System Water-Mission SL-4 2.2.11-35 Test Summary Sheet - OWS Whole Body Shower Water 2.2.11-418 Bottle Module Assembly Refrigeration System Design Requirements 2.2.11-466 ICD 13M20926 Food Storage Requirements 2.2.11-468 Major Design Parameters 2.2.11-469 Refrigeration System Development and...

Ref B

During initi.nl om-rationr.-entrv ami emergency-lighting conditions. A switch was provided on each lamp assembly for off-low-high control of each light, independently. Tlu> end of the preinstaileu light housing assembly was indexed to the switch on the light bulb. The bulb has an attached pigtail with a zero-g connector that allows one-handed replacement. A hinged cover on the housing assembly protected the pigtail after installation and supported the lamp. Design and construction details on...

Uc

Have been proven through various tests. Specifically, this model has demonstrated design performance in its production acceptance tests, handling and checkout tests, and the OWS test control procedures . Mission Results - Performance During Service and Checkout - The items of GSE design to service and checkout the OWS-RS performed satisfactorily and met the design requirements imposed upon them. There were no cases of major redesign or resultant schedule impact on the vehicle. Some of the more...

Cartridge Retention

The hinged compartment door provided access to the cartridges to facilitate removal and loading operations while also providing access openings on its face through which tissues may be obtained. A spring-loaded dispenser lid covered each access opening on the compartment door to provide flamma-bility control of the combustible tissue. The cartridge retainer and cartridge retention cams restrained each cartridge within the dispenser. The cams permitted easy removal and replacement of a...

Vehicle

*(U.32 x 107 hr) **(l.26 x I07 j hr) ***(l.26 x 107 J hr) the heaters and uses 28 vdc for commands and indications. The fluid control unit (FCU) , through a pressure trtjisducer, monitors the pressure of f-j water glycol. Solenoid valves in the FCU can redirect the flow of the water glycol from the GCHX to a coolant dump in ground equipment. The FCU maintains GN pressure supplied to purge the GCHX, and there is a pressure transducer to monitor the GN pressure. The solenoid valve is controlled...

Rationale For

Torque Stripes at Bolted Connections Rates are within limits at time of deployment of optical surfaces. Ref. Attachment I. Temperature is less than 250 F (391* K). Ref. PM-SL-SW-669-71, 6-11-71. Ref. A3-250-AAAA-M-1U, 8-U71. Rates are within limits at time of deployment of optical surfaces. Ref. P0327 Supp No. 10501. Rates are witbin limits at time of deployment of optical surfaces. Ref. Test Data Sheet No. 950OU, Sept. 1970. Index Marks for Alignment of Interstages with 0V7S Six index marts...

Lfh Under Test

The leak detector consists of a suitcase containing a differential pressure gage with a reference volume attached to one side and a flex hose that connects to the vehicle system under test on the other side. 1c also includes pressure gages, relief valves, shutoff valves, adapters and associated plumbing. It is a portable, self-contained unit and can be used within the OWS to measure the leak decay rate of the RS, tne trash airlock, the Environmental Control System (ECS) ground heat exchanger,...

Tcd Tuw Ctca

The thrust, radial and tangential, both random and sinusoidal ibra-tion tests were performed on a four drawer test fixture to simulate the vibration profiles to the NASA supp ied test specimens. After the tests the specimens were turned oter tc the NASA representatives. There were no MDAC objectives in this test. Sinusoidal and random vibration tests were performed on the following Specimen No. 1 (1) 16 MM Transport Mechanism, SEB 33100278-301 Specimen No. 2 (2) lb MM Film Magazine, SEB...

E

The operation is based on the sequenci ng of three counters -the temperature counter, the power supply counter and the module counter. The sequencing of the counters and the decoded output of the counters can be controlled by front panel switches. The temperature counter function is to automatically sequence a matrix that switches resistance temperature bulbs TF3's on the SAS wing to the input of a digital voltmeter. The power supply to the proper voltage values as determined by front panel...

Reproducibility Of The Original Page Is Poor

To meet the flammability nd outgassing requirements of 1BT8110 were P537 pile Fluore.1 coated beta glass tape with etched TFE pile and H5T2 hook Fluorel coated Beta glass tape with PBI hooks . B. Usages 1 After May 1971 the H572 hook .006 in. .152 mm diameter PBI fiber wa.s replaced by H6l6 PBI hook .008 in .203 mm diameter PBI fiber , by the suppliers own volition. 2 Toward the end of the OWS nro lt ran a shorage of PBI fiber occurred and che 16I0 hoo tape had to be replaced with 115 9...