II r

DUAL SHIFT ORBITER CO2 ABSORBER REPLACEMENT (Front) CC 15-17 ORB OPS-11a nonRCRS B (Back) CC 15-18 ORB OPS-11b nonRCRS B (Front) CC 15-19 ORB OPS-12a nonRCRS B (Back) CC 15-20 ORB OPS-12b nonRCRS B (Front) CC 15-21 ORB OPS-13a nonRCRS B (Back) CC 15-22 ORB OPS-13b nonRCRS B (Front) CC 15-23 ORB OPS-14a nonRCRS B (Back) CC 15-24 ORB OPS-14b nonRCRS B (Front) CC 15-25 ORB OPS-15a nonRCRS B (Back) CC 15-26 ORB OPS-15b nonRCRS B (Front) CC 15-27 ORB OPS-16a nonRCRS B (Back) CC 15-28 ORB OPS-16b...

R

After 15 sec, verify nominal display (gas concentrations) 17. VDisplay readings for CO, HCN, HCL less than If readings higher than values below, notify MCC CO < 4 ppm HCL < 0.4 ppm HCN < 0.4 ppm 19. Remove Zero Filter from Sampling Pump inlet Replace tethered endcaps and tighten finger tight Damage to O-ring can occur if overtightened 21. Replace Sampling Pump Inlet Filter and tighten until snug CSA-CP can be used in active sampling mode using pump or in passive mode without pump. Use of...

To G Transition

No KYBD item entries or sw throws 10 sec before and after moding PASS GPCs to RUN or making OPS transition requests If reqd, perform LOAD PCMMU FORMAT (ORB OPS FS, COMM INST) 2. G2 OPS TRANSITION O14,O15 F VMMU (two) - ON Pause 30 sec (DAP settling) C3(A6U) DAP as reqd NOTE Downlist reverts to lowest GPC (MCC may request Item 44+X) S TRK -Y,-Z STAR TRK - ITEM 3,4 EXEC (*) GNC 21 IMU ALIGN RESUME O15 F If reqd for PWRDN MMU 2 - OFF If not currently performing FCS Checkout, then O8 VMLS (three) -...

Fc Monitoring Sys Fcms

Recorded data file names will have the format fcDDDHHMM.fcv and be compressed as fcDDDHHMM.zip where 'DDDHHMM' refers to the GMT of the first data point. Recorded data files will contain single cell voltages from all three fuel cells. WinDecom-FCMS can be run on either the WinDecom PGSC or another PGSC with a PCMMU expansion unit. The FCMS application can be run on a PGSC running WinDecom-FCMS or a PGSC connected (via network or serial) to a PGSC running WinDecom-FCMS. The FCMS cable pin out is...

Kubd Ant Jettison

Jettison between sunrise and noon if possible AUTO MNVR TO -XLV VSTART TIME at least 15 min prior to sunrise VTGT ID 2 BODY VECT 2 OM 0 START TRK - ITEM 19 EXEC CUR- DAP A AUTO VERN CONFIGURE KU FOR JETTISON VKU BD PWR - OFF CNTL - PNL cb MNB KU ELEC - op ANT HTR - op CABLE HTR - op MNC KU SIG PROC - op VPYRO KU ANT two - SAFE MCA LOGIC MNC MID 2 - OFF MNB MID 4 - OFF cb MNA PYRO JETT SYS A KU ANT - cl MNC PYRO JETT SYS B KU ANT - cl SET UP PLB CAMRS, RECORDING DEVICES Perform...

Oca Sband Modem Mfx Activation

ESTABLISH LINK On MCC GO A15 PS COMM CCU PWR - OFF ICOM two - OFF VOL A G 2 tw - 0 XMIT ICOM MODE - PTT PTT Loss of A A UHF will occur if OCA PGSC Modem cable connected to COMM OUTLET and A A in T R on ATU R AUD A G 2 - OFF L AUD A G 2 - OFF MS AUD A G 2 - OFF MIDDECK SPKR AUD A G 2 - OFF VPGSC Modem cable connected to PS COMM outlet ACTIVATE FILE XFER S W If PGSC not running Windows 98 Restart or pwr on PGSC Within 15 sec, click on 'STS PGSC' at 'Boot Magic' bootup menu Sel 'Docked OCA Card...

Usa

Verify this is the correct version for the pending operation training, simulation or flight . Electronic copies of FDF books are available. URL GENERIC, REVISION K November 22, 2004 KlmbeWy .Ulohnson Michael T. Hurt This document is under the configuration control of the Crew Procedures Control Board CPCB . AH proposed changes must be submitted on FDF Workflow Crew Procedure Change Request CR to D03 FDF Manager. Additional distribution of this book, for official use only, may be requested in...

Onorbit Oms Burn

OMS BURN PREP C2 Install OMS-2 ORBIT OMS BURNS Wedge Cue Cards two and ORBIT BURN CNCL - ITEM 21 EXEC GNC, OPS 202 PRO F7 VOMS PRESS He TK L R gt 640 psia WARNING If OMS PRESS not within limits, do not execute on-orbit burn O14 F, VPri RJD LOGIC,DRIVER sixteen - ON O15 F, O16 F O14 E, Vcb DDU six - cl O15 E, O16 E

Windecom

Unstow data cables, cards, adapters PCMMU data cable if not prerouted RS-232 Y data cable if reqd RS-422 Y data cable if reqd RS-422 PCMCIA cards, adapter boxes if reqd MO30F f using pnl O5 to receive PCMMU feed, verify jumper plug connected to PCMMU 1 2 outlet f using pnl MO30F to receive PCMMU feed, disconnect jumper plug from PCMMU 1 2 outlet O5 3. Connect PCMMU data cable from PCMMU 1 2 MO30F outlet to PGSC PCMMU expansion card port 4. If sending WinDecom data via serial See UTILITY...